Hi-Fidelity Power Supply in Your Future??
Anderson Electric Controls has a IGBT based Power Supply for design and development of Inverters in the Transportation Industry.
Features
Power Range from 36kW to 360kW Continuous, 133% O/L for 3 Seconds
Two Quadrant, Regenerative to Utility Line (IEEE 519)
Output Voltage Continuously Variable
Constant Current 8% of Nominal Volts 60, 120, 345, 500 (4 models 150VDC, 300 VDC, 600VDC, 900VDC Maximum)
Constant Power from nominal Volts DC to Maximum VDC
Output Current 600, 300, 580, 400 Amps Continuous, 133% Amps Peak for 3 Seconds Higher amps available on lower voltage units (up to 1200ADC).
AC Input 415/480VAC, 3 Phase 50/60 Hz.
Automatic Transition from Source to Sink.
Compact, Air Cooled Package—82”H x 45”W x 34”D
Enclosure on Casters for Portability
Isolation Transformer Standard. Built into cabinet on Low Voltage units150VDC or less.
Automatic or Manual Control with Digital Display of Voltage and Current, Lighted Control Switches and Safety Indicators
Bumpless Transfer Between Automatic and Manual Control
Automatic Profile Control via FiberOptic, USB or Ethernet Link to ACSYSdyne Host Controller
Digital Data Bus, RS-422, USB, Ethernet or CANbus
Remote Voltage Sense Capability
Overvoltage Protection
3 phase 480 VAC Input Power
Battery Resistance Simulation 0-500 milliohm
Output isolation contactors included in all designs
120 VAC Input for Control
Built in Shunt Regulator for Power Outage Protection.
Specifications
Transition Time: < 0.11 msec Source to Sink.
Step Response Time: < 10msec for 10/90% or 90/10% changes at rated current.
Voltage Sag: < 3.0% during step response.
Transient Regulation: +/- 3.0% for all line and load variations.
Steady State Regulation: +/- 0.5%.
Voltage Ripple: 2.0% peak-to-peak in voltage range.
|
|

|
Inside view of a 200 kW 600VDC power supply.
|
|
Upper left corner - 3U DSP controller
Upper middle - Gatedrive interface
Middle left side - Shunt IGBT
Middle left - chopper IGBT bridge
Middle right - PWM converter IGBT bridge.
The shunt is an option for power ride through in case of an incoming power failure during regeneration.
The power supply can be scaled up or down in power and voltage
The controller and gate circuits are capable of driving 1700, 1200, 600 and 250 volt IGBTs
The power factor is unity and the total harmonic current distortion is less than 5% on the mains input
The power supply can be controlled remotely by a USB, Ethernet or an optional high speed fiber optic interface
ACSYSdyne is required for the fiber optic communications
ACSYSoft is used for USB and Ethernet communications
|
|